Availability: | |
---|---|
Quantity: | |
Brief Introduction
With robust construction and precise engineering, the UMEK RO Membrane Plant ensures reliable and consistent performance, providing a continuous supply of high-quality water for various industrial processes. It offers customizable solutions to meet specific water quality and quantity requirements, catering to diverse industries such as manufacturing, power generation, pharmaceuticals, and more.
RO membrane Plant come in a variety of sizes and types. In addition to the common 1812, 2521, 8080 and 4040 sizes, there are other models dedicated to different scenarios.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
UMK21-8040 | 11500(45.7) | 99.0 | 98.5 |
UMK22-8040 | 10500(39.7) | 99.5 | 99.0 |
UMK11-4040 | 2600(9.1) | 99.0 | 98.5 |
UMK-HR-4040 | 2000(7.6) | 99.6 | 99.3 |
Testing Conditions:
Testing Pressure: 150 psi (1.03Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 1500ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
High-Rejection (HR): The HR type is similar in dimensions to the standard elements but is specifically designed for high-rejection applications, such as seawater desalination. These membranes have enhanced salt rejection capabilities, making them suitable for treating highly saline water sources.
Low-Pressure (LP): The LP type is designed to operate at lower pressures, which can result in energy savings and reduced operating costs. These elements are ideal for applications where energy efficiency is a priority.
Extra-Low Energy (XLE): The XLE type is optimized for low-energy consumption. These elements are engineered to operate efficiently at lower pressures, helping to minimize energy requirements while maintaining water quality.
Brackish Water: The Brackish Water type is specifically designed for treating brackish water sources, such as groundwater with moderate salinity levels. These membranes are designed to provide efficient and cost-effective treatment for brackish water applications.
Brief Introduction
With robust construction and precise engineering, the UMEK RO Membrane Plant ensures reliable and consistent performance, providing a continuous supply of high-quality water for various industrial processes. It offers customizable solutions to meet specific water quality and quantity requirements, catering to diverse industries such as manufacturing, power generation, pharmaceuticals, and more.
RO membrane Plant come in a variety of sizes and types. In addition to the common 1812, 2521, 8080 and 4040 sizes, there are other models dedicated to different scenarios.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
UMK21-8040 | 11500(45.7) | 99.0 | 98.5 |
UMK22-8040 | 10500(39.7) | 99.5 | 99.0 |
UMK11-4040 | 2600(9.1) | 99.0 | 98.5 |
UMK-HR-4040 | 2000(7.6) | 99.6 | 99.3 |
Testing Conditions:
Testing Pressure: 150 psi (1.03Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 1500ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
High-Rejection (HR): The HR type is similar in dimensions to the standard elements but is specifically designed for high-rejection applications, such as seawater desalination. These membranes have enhanced salt rejection capabilities, making them suitable for treating highly saline water sources.
Low-Pressure (LP): The LP type is designed to operate at lower pressures, which can result in energy savings and reduced operating costs. These elements are ideal for applications where energy efficiency is a priority.
Extra-Low Energy (XLE): The XLE type is optimized for low-energy consumption. These elements are engineered to operate efficiently at lower pressures, helping to minimize energy requirements while maintaining water quality.
Brackish Water: The Brackish Water type is specifically designed for treating brackish water sources, such as groundwater with moderate salinity levels. These membranes are designed to provide efficient and cost-effective treatment for brackish water applications.
On July 27, 2024, my colleague Carlson and I departed from Terminal 2 of Beijing Capital International Airport and arrived in Tashkent, the capital of Uzbekistan, after a 6-hour flight. Uzbekistan is an inland country in Central Asia. Russian is the common language, with a population of 36.8 million
On April 6, 2024, two representatives from our company, Youmankang, arrived in Lebanon, a country in the Middle East known for its breathtaking landscapes. With buildings nestled on hillsides, water trucks can be seen everywhere on the streets, indicating the underdeveloped seawater desalination tec
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to