Availability: | |
---|---|
Quantity: | |
A reverse osmosis membrane is a semi-permeable membrane synthesised using a special process in order to achieve the phenomenon of reverse osmosis of an aqueous solution.
The pore size of a reverse osmosis membrane is 0.0001 microns (μm), and only the solvent in the aqueous solution - water - can pass through, while its solutes cannot pass through the reverse osmosis membrane.
In the water purification system of a water purifier, the reverse osmosis membrane refers exclusively to the formed reverse osmosis membrane cartridge. The reverse osmosis membrane cartridge is the core component of the water purification system of a water purifier, and only with the use of a reverse osmosis membrane can it be called a water purifier.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
Function
The use of ultra-static pressure pumps to generate high pressure osmosis, so that water molecules and ionic mineral elements through a layer of reverse osmosis membrane, while the vast majority of heavy metals, organic matter, as well as bacteria, viruses, etc. dissolved in the water can not be retained through the reverse osmosis membrane.
With the principle of reverse osmosis, impure substances such as pyrogens, filtered viruses, bacteria, toxins, compounds, heavy metals (arsenic, cobalt, cadmium, mercury, etc.), toxic substances, metals, salts, free ions and other substances hazardous to human health are removed from the water. The reverse osmosis membrane isolates impurities from pure water and creates pure drinking water.
If you would like to know more about our RO membranes, please contact us!
A reverse osmosis membrane is a semi-permeable membrane synthesised using a special process in order to achieve the phenomenon of reverse osmosis of an aqueous solution.
The pore size of a reverse osmosis membrane is 0.0001 microns (μm), and only the solvent in the aqueous solution - water - can pass through, while its solutes cannot pass through the reverse osmosis membrane.
In the water purification system of a water purifier, the reverse osmosis membrane refers exclusively to the formed reverse osmosis membrane cartridge. The reverse osmosis membrane cartridge is the core component of the water purification system of a water purifier, and only with the use of a reverse osmosis membrane can it be called a water purifier.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
Function
The use of ultra-static pressure pumps to generate high pressure osmosis, so that water molecules and ionic mineral elements through a layer of reverse osmosis membrane, while the vast majority of heavy metals, organic matter, as well as bacteria, viruses, etc. dissolved in the water can not be retained through the reverse osmosis membrane.
With the principle of reverse osmosis, impure substances such as pyrogens, filtered viruses, bacteria, toxins, compounds, heavy metals (arsenic, cobalt, cadmium, mercury, etc.), toxic substances, metals, salts, free ions and other substances hazardous to human health are removed from the water. The reverse osmosis membrane isolates impurities from pure water and creates pure drinking water.
If you would like to know more about our RO membranes, please contact us!
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to
We are excited to invite you to visit Booth No. 238 at the upcoming 2024 WQA exhibition in Orlando, FL, USA. At our booth, we will be showcasing a range of cutting-edge water treatment solutions, including our flagship product, RO membranes.Reverse Osmosis (RO) membranes are at the heart of our wate
Reverse osmosis membranes play a crucial role in water purification by effectively removing dissolved salts, colloids, microorganisms, and organic compounds. However, the performance of these membranes can deteriorate due to various factors such as surface fouling, physical and chemical changes, and