Dow RO membrane elements offer superior quality and performance for the separation of contaminants in concentrated water resulting in purified, clean drinking water.
Availability: | |
---|---|
Quantity: | |
DOW reverse osmosis (RO) membranes for home drinking water treatment units are among the most reliable and consistent elements in the industry.
Advanced membrane technology and automated fabrication allow Dow to precisely produce each and every element to tight, pre-defined specifications.
Dow’s advanced and consistent RO element quality helps customers deliver systems that reliably provide low impurity drinking water.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Membrane Type: Thin Film Composite
Maximum Operating Temperature: 110°F (43°C)
Maximum Operating Pressure: 125 PSI
Maximum Feed Flow Rate: 1 GPM
Minimum Concentrate Flow Rate: 4 x Permeate
pH Range, Continuous Operation: 3 - 11
Maximum Feed Water Turbidity: 1 NTU
Maximum Feed Silt Density Index (SDI): 5 SDI
Chlorine Tolerance: 0 PPM
Important information
This high quality reverse osmosis membrane is widely used in household water purifiers, aquariums and other small commercial water purification equipment.
Remove heavy metals (mainly calcium and magnesium), bacteria and any other carbonate particles from the water source.
If you would like to know more about our RO membranes, please contact us!
DOW reverse osmosis (RO) membranes for home drinking water treatment units are among the most reliable and consistent elements in the industry.
Advanced membrane technology and automated fabrication allow Dow to precisely produce each and every element to tight, pre-defined specifications.
Dow’s advanced and consistent RO element quality helps customers deliver systems that reliably provide low impurity drinking water.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Membrane Type: Thin Film Composite
Maximum Operating Temperature: 110°F (43°C)
Maximum Operating Pressure: 125 PSI
Maximum Feed Flow Rate: 1 GPM
Minimum Concentrate Flow Rate: 4 x Permeate
pH Range, Continuous Operation: 3 - 11
Maximum Feed Water Turbidity: 1 NTU
Maximum Feed Silt Density Index (SDI): 5 SDI
Chlorine Tolerance: 0 PPM
Important information
This high quality reverse osmosis membrane is widely used in household water purifiers, aquariums and other small commercial water purification equipment.
Remove heavy metals (mainly calcium and magnesium), bacteria and any other carbonate particles from the water source.
If you would like to know more about our RO membranes, please contact us!
On July 27, 2024, my colleague Carlson and I departed from Terminal 2 of Beijing Capital International Airport and arrived in Tashkent, the capital of Uzbekistan, after a 6-hour flight. Uzbekistan is an inland country in Central Asia. Russian is the common language, with a population of 36.8 million
On April 6, 2024, two representatives from our company, Youmankang, arrived in Lebanon, a country in the Middle East known for its breathtaking landscapes. With buildings nestled on hillsides, water trucks can be seen everywhere on the streets, indicating the underdeveloped seawater desalination tec
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to