Dow RO membrane elements offer superior quality and performance for the separation of contaminants in concentrated water resulting in purified, clean drinking water.
Availability: | |
---|---|
Quantity: | |
DOW reverse osmosis (RO) membranes for home drinking water treatment units are among the most reliable and consistent elements in the industry.
Advanced membrane technology and automated fabrication allow Dow to precisely produce each and every element to tight, pre-defined specifications.
Dow’s advanced and consistent RO element quality helps customers deliver systems that reliably provide low impurity drinking water.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Membrane Type: Thin Film Composite
Maximum Operating Temperature: 110°F (43°C)
Maximum Operating Pressure: 125 PSI
Maximum Feed Flow Rate: 1 GPM
Minimum Concentrate Flow Rate: 4 x Permeate
pH Range, Continuous Operation: 3 - 11
Maximum Feed Water Turbidity: 1 NTU
Maximum Feed Silt Density Index (SDI): 5 SDI
Chlorine Tolerance: 0 PPM
Important information
This high quality reverse osmosis membrane is widely used in household water purifiers, aquariums and other small commercial water purification equipment.
Remove heavy metals (mainly calcium and magnesium), bacteria and any other carbonate particles from the water source.
If you would like to know more about our RO membranes, please contact us!
DOW reverse osmosis (RO) membranes for home drinking water treatment units are among the most reliable and consistent elements in the industry.
Advanced membrane technology and automated fabrication allow Dow to precisely produce each and every element to tight, pre-defined specifications.
Dow’s advanced and consistent RO element quality helps customers deliver systems that reliably provide low impurity drinking water.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Membrane Type: Thin Film Composite
Maximum Operating Temperature: 110°F (43°C)
Maximum Operating Pressure: 125 PSI
Maximum Feed Flow Rate: 1 GPM
Minimum Concentrate Flow Rate: 4 x Permeate
pH Range, Continuous Operation: 3 - 11
Maximum Feed Water Turbidity: 1 NTU
Maximum Feed Silt Density Index (SDI): 5 SDI
Chlorine Tolerance: 0 PPM
Important information
This high quality reverse osmosis membrane is widely used in household water purifiers, aquariums and other small commercial water purification equipment.
Remove heavy metals (mainly calcium and magnesium), bacteria and any other carbonate particles from the water source.
If you would like to know more about our RO membranes, please contact us!
You can’t see them. You can’t taste them.But they’re in the water you drink, the food you eat, and even the air you breathe.These invisible pollutants are called PFAS—short for per- and polyfluoroalkyl substances. Often referred to as “forever chemicals”, PFAS have gained global attention for their
Amanda & Umek are dedicated to delivering efficient solutions and high-quality services to the global water treatment industry. In order to better understand the South African market, listen to customer feedback, and explore potential cooperation opportunities, our professional team will be visiting
On June 6, 2025, the 17th Watertech China successfully wrapped up its three-day event at the National Exhibition and Convention Center (Hongqiao) in Shanghai. As one of the world’s leading trade shows for the water treatment industry, it brought together cutting-edge technologies and innovative prod