Availability: | |
---|---|
Quantity: | |
The quality of the membrane components meets international standards, the main raw materials and accessories are selected according to NSF standards in the United States, and the main technical indicators reach or exceed those of imported products, leading Asia.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
General conditions of use
1. The storage location must be cool (not higher than 45°C) and dry without direct sunlight.
2. For initial commissioning and initial operation of the reverse osmosis membrane element, the pure and concentrated water should be discharged within the first hour after start-up.
3. Once the dry membrane element is wet, it should always be kept moist.
4.To prevent microbial growth in wet membrane elements, it is recommended that the elements are soaked in a protective solution containing 1.0% sodium metabisulphite (food grade) and then vacuum packed in a cardboard box.
5. It is forbidden to add any chemicals that may affect the membrane element and Yoxing Water Purification will not be held responsible for any consequences arising from the use of such chemicals.
The quality of the membrane components meets international standards, the main raw materials and accessories are selected according to NSF standards in the United States, and the main technical indicators reach or exceed those of imported products, leading Asia.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
General conditions of use
1. The storage location must be cool (not higher than 45°C) and dry without direct sunlight.
2. For initial commissioning and initial operation of the reverse osmosis membrane element, the pure and concentrated water should be discharged within the first hour after start-up.
3. Once the dry membrane element is wet, it should always be kept moist.
4.To prevent microbial growth in wet membrane elements, it is recommended that the elements are soaked in a protective solution containing 1.0% sodium metabisulphite (food grade) and then vacuum packed in a cardboard box.
5. It is forbidden to add any chemicals that may affect the membrane element and Yoxing Water Purification will not be held responsible for any consequences arising from the use of such chemicals.
Dive into the future of aquatic technology at the highly anticipated 2023 Shanghai Aquatech Exhibition. We UMEK cordially invite you to join us at this extraordinary event where groundbreaking innovations, cutting-edge solutions, and limitless possibilities in the world of aquatic technology await.
Pure water, also known as purified water, refers to water that meets the standard for drinking water, and is water that can be directly supplied for drinking after the source water is treated by ion exchange, reverse osmosis, distillation or other methods and then sealed and kept in a container. Yib
WQA Convention & Exposition 2023 will be held in Las Vegas, Nevada, USA, from April 18-20, 2023.For this reason, we have organized a professional trade show simulation. We never fight unprepared battles and we never simply deal with our customers.For this exhibition simulation, we prepared very comp