High rejection stability at high input TDS
Standard size fits commonly used housings
Reverse osmosis membranes allow pure water to pass through the membrane while discharging many contaminants such as viruses, bacteria, heavy metals, fluoride and salts into the waste stream.
Our reverse osmosis membranes are thin film composite membranes and TFC membranes offer the best in productivity, recovery and retention. These membranes offer high performance and durability with optimal retention rates for increased pure water production in high TDS waters.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
Extreme usage conditions
Maximum operating pressure: 300psi (2.07Mpa)
Maximum inlet water temperature: 45°C
Maximum water intake SDI: 5
Influent free chlorine concentration: <0.1 ppm
Influent pH range during continuous operation: 3~10
pH range of inlet water during chemical cleaning: 2~ 12
Maximum pressure drop of a single membrane element: 10psi (0.07Mpa)
Membrane element size
All units of the icon are: mm (inch)
FAQ
1. Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
2. Q: Should we use our logo/brand?
A: Yes, OEM is absolutely supported. But for some items quatity is 1000pcs
3. Q: What is the filtering accuracy of RO membrane?
A: RO meembran filtering accuracy is 0.0001um.
4.RO membrene desalination rate and service life ?
A: RO meembran desalination rate more 98%,service life according to water quality 2-3years
5. Q: What is the payment?
A: Usually we offer two payment terms: by Alibaba or by TT. L/C and D/A.
6. Q: How long time have your company in water treatment?
A: We have more than 21 years experience in water treatment equipment/water treatment solution.
High rejection stability at high input TDS
Standard size fits commonly used housings
Reverse osmosis membranes allow pure water to pass through the membrane while discharging many contaminants such as viruses, bacteria, heavy metals, fluoride and salts into the waste stream.
Our reverse osmosis membranes are thin film composite membranes and TFC membranes offer the best in productivity, recovery and retention. These membranes offer high performance and durability with optimal retention rates for increased pure water production in high TDS waters.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
Extreme usage conditions
Maximum operating pressure: 300psi (2.07Mpa)
Maximum inlet water temperature: 45°C
Maximum water intake SDI: 5
Influent free chlorine concentration: <0.1 ppm
Influent pH range during continuous operation: 3~10
pH range of inlet water during chemical cleaning: 2~ 12
Maximum pressure drop of a single membrane element: 10psi (0.07Mpa)
Membrane element size
All units of the icon are: mm (inch)
FAQ
1. Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
2. Q: Should we use our logo/brand?
A: Yes, OEM is absolutely supported. But for some items quatity is 1000pcs
3. Q: What is the filtering accuracy of RO membrane?
A: RO meembran filtering accuracy is 0.0001um.
4.RO membrene desalination rate and service life ?
A: RO meembran desalination rate more 98%,service life according to water quality 2-3years
5. Q: What is the payment?
A: Usually we offer two payment terms: by Alibaba or by TT. L/C and D/A.
6. Q: How long time have your company in water treatment?
A: We have more than 21 years experience in water treatment equipment/water treatment solution.
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to
We are excited to invite you to visit Booth No. 238 at the upcoming 2024 WQA exhibition in Orlando, FL, USA. At our booth, we will be showcasing a range of cutting-edge water treatment solutions, including our flagship product, RO membranes.Reverse Osmosis (RO) membranes are at the heart of our wate
Reverse osmosis membranes play a crucial role in water purification by effectively removing dissolved salts, colloids, microorganisms, and organic compounds. However, the performance of these membranes can deteriorate due to various factors such as surface fouling, physical and chemical changes, and