Can effectively remove dissolved salts, colloids, microorganisms, and organic matter in water.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
Production Process
Can effectively remove dissolved salts, colloids, microorganisms, and organic matter in water.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
Production Process
First of all, you should have a water pressure meter, you test the pressure of the waste water, if the pressure value is above 6KG, it means that the RO membrane may be blocked. Or you have a TDS or conductivity meter, you test the water quality if the TDS value of the water is very high, then the d
China Commodities Expo Nigeria was held as scheduled from November 8, 2022 - November 11, 2020.During the exhibition, our team members answered questions from a professional perspective for many customers and provided diverse solutions for the industry.Exhibition Overview The show was packed with ex