Availability: | |
---|---|
Quantity: | |
Brief Introduction
The ULP series membrane elements are suitable for the desalination of RO produced water, groundwater, tap water and municipal water with a salt content of less than 2000ppm, and are mainly used in various fields such as pure water, boiler make-up water, food processing and pharmaceutical manufacturing industries.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
IU21-8040 | 11500(45.7) | 99.0 | 98.5 |
IU22-8040 | 10500(39.7) | 99.5 | 99.0 |
IU11-4040 | 2600(9.1) | 99.0 | 98.5 |
IU-HR-4040 | 2000(7.6) | 99.6 | 99.3 |
Testing Conditions:
Testing Pressure: 150 psi (1.03Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 1500ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4. 14Mpa)
Max. Feedwater Flow: 75gpm(17 m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwater: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0.1Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
Brief Introduction
The ULP series membrane elements are suitable for the desalination of RO produced water, groundwater, tap water and municipal water with a salt content of less than 2000ppm, and are mainly used in various fields such as pure water, boiler make-up water, food processing and pharmaceutical manufacturing industries.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
IU21-8040 | 11500(45.7) | 99.0 | 98.5 |
IU22-8040 | 10500(39.7) | 99.5 | 99.0 |
IU11-4040 | 2600(9.1) | 99.0 | 98.5 |
IU-HR-4040 | 2000(7.6) | 99.6 | 99.3 |
Testing Conditions:
Testing Pressure: 150 psi (1.03Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 1500ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4. 14Mpa)
Max. Feedwater Flow: 75gpm(17 m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwater: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0.1Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
On April 6, 2024, two representatives from our company, Youmankang, arrived in Lebanon, a country in the Middle East known for its breathtaking landscapes. With buildings nestled on hillsides, water trucks can be seen everywhere on the streets, indicating the underdeveloped seawater desalination tec
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to
We are excited to invite you to visit Booth No. 238 at the upcoming 2024 WQA exhibition in Orlando, FL, USA. At our booth, we will be showcasing a range of cutting-edge water treatment solutions, including our flagship product, RO membranes.Reverse Osmosis (RO) membranes are at the heart of our wate