Availability: | |
---|---|
Quantity: | |
Brief Introduction
ULP 4040 RO Membrane is mainly used for the desalination of surface water, groundwater and municipal water with a salt content of up to 2000mg/L.
Its application areas include packaged drinking water, subdivision or park water supply, food and beverage, etc. It has the characteristics of high water production, low operating pressure and good desalination performance.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
IU21-8040 | 11500(45.7) | 99.0 | 98.5 |
IU22-8040 | 10500(39.7) | 99.5 | 99.0 |
IU11-4040 | 2600(9.1) | 99.0 | 98.5 |
IU-HR-4040 | 2000(7.6) | 99.6 | 99.3 |
Testing Conditions:
Testing Pressure: 150 psi (1.03Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 1500ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4. 14Mpa)
Max. Feedwater Flow: 75gpm(17 m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwater: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0.1Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
Brief Introduction
ULP 4040 RO Membrane is mainly used for the desalination of surface water, groundwater and municipal water with a salt content of up to 2000mg/L.
Its application areas include packaged drinking water, subdivision or park water supply, food and beverage, etc. It has the characteristics of high water production, low operating pressure and good desalination performance.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
IU21-8040 | 11500(45.7) | 99.0 | 98.5 |
IU22-8040 | 10500(39.7) | 99.5 | 99.0 |
IU11-4040 | 2600(9.1) | 99.0 | 98.5 |
IU-HR-4040 | 2000(7.6) | 99.6 | 99.3 |
Testing Conditions:
Testing Pressure: 150 psi (1.03Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 1500ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4. 14Mpa)
Max. Feedwater Flow: 75gpm(17 m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwater: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0.1Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)