Availability: | |
---|---|
Quantity: | |
Brief Introduction
SW series membrane elements are generally suitable for the treatment of seawater and highly concentrated brackish water, and can be used for desalination of seawater, desalination of highly concentrated brackish water, power plant boiler make-up water and other industrial water treatment, as well as for the reuse of waste water, concentration and recovery of high value-added substances such as food and pharmaceuticals.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
SW30HRLE-8040 | 7500(28.4) | 99.85 | 99.6 |
SW30XLE-8040 | 9000(34.1) | 99.8 | 99.6 |
SW-4040 | 1400(5.3) | 99.7 | 99.5 |
Testing Conditions:
Testing Pressure: 800 psi (5.5Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCI): 32000ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 1000psi(6.9Mpa)
Max. Feedwater Flow: 75gpm(17m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwate: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0. 1Mpa)
Dimensions of Membrane Element
All dlimensions are shown in: millimeter (inch)
Brief Introduction
SW series membrane elements are generally suitable for the treatment of seawater and highly concentrated brackish water, and can be used for desalination of seawater, desalination of highly concentrated brackish water, power plant boiler make-up water and other industrial water treatment, as well as for the reuse of waste water, concentration and recovery of high value-added substances such as food and pharmaceuticals.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
SW30HRLE-8040 | 7500(28.4) | 99.85 | 99.6 |
SW30XLE-8040 | 9000(34.1) | 99.8 | 99.6 |
SW-4040 | 1400(5.3) | 99.7 | 99.5 |
Testing Conditions:
Testing Pressure: 800 psi (5.5Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCI): 32000ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 1000psi(6.9Mpa)
Max. Feedwater Flow: 75gpm(17m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwate: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0. 1Mpa)
Dimensions of Membrane Element
All dlimensions are shown in: millimeter (inch)
First of all, you should have a water pressure meter, you test the pressure of the waste water, if the pressure value is above 6KG, it means that the RO membrane may be blocked. Or you have a TDS or conductivity meter, you test the water quality if the TDS value of the water is very high, then the d
China Commodities Expo Nigeria was held as scheduled from November 8, 2022 - November 11, 2020.During the exhibition, our team members answered questions from a professional perspective for many customers and provided diverse solutions for the industry.Exhibition Overview The show was packed with ex
Time: 8 Nov.-11 Nov.2022Exhibition Address: Landmark Centre, Lagos, NigeriaBooth : A27-A28 We will be in Nigeria from November 6th to December 10th to prepare for the Exhibition. Looking forward to our meeting! WeChat/WhatsApp: +86-13393211007 à Email: sales@cnumek.com