We are RO membrane manufacturer. we manufacture 50 GPD 75GPD 100 GPD Domestic RO Membrane with excellent performance at highly economical price. for price please contact us.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
Extreme usage conditions
Maximum operating pressure: 300psi (2.07Mpa)
Maximum inlet water temperature: 45°C
Maximum water intake SDI: 5
Influent free chlorine concentration: <0.1 ppm
Influent pH range during continuous operation: 3~10
pH range of inlet water during chemical cleaning: 2~ 12
Maximum pressure drop of a single membrane element: 10psi (0.07Mpa)
Membrane element size
All units of the icon are: mm (inch)
FAQ
1. Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
2. Q: Should we use our logo/brand?
A: Yes, OEM is absolutely supported. But for some items quatity is 1000pcs
3. Q: What is the filtering accuracy of RO membrane?
A: RO meembran filtering accuracy is 0.0001um.
4.RO membrene desalination rate and service life ?
A: RO meembran desalination rate more 98%,service life according to water quality 2-3years
5. Q: What is the payment?
A: Usually we offer two payment terms: by Alibaba or by TT. L/C and D/A.
6. Q: How long time have your company in water treatment?
A: We have more than 21 years experience in water treatment equipment/water treatment solution.
We are RO membrane manufacturer. we manufacture 50 GPD 75GPD 100 GPD Domestic RO Membrane with excellent performance at highly economical price. for price please contact us.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
Test conditions: Test pressure: 100 psi (0.69Mpa)
Test fluid temperature: 25 °C
Test solution concentration (NaCI): 250ppm
pH value of test solution: 7.5
Single membrane element recovery rate: 20%
Extreme usage conditions
Maximum operating pressure: 300psi (2.07Mpa)
Maximum inlet water temperature: 45°C
Maximum water intake SDI: 5
Influent free chlorine concentration: <0.1 ppm
Influent pH range during continuous operation: 3~10
pH range of inlet water during chemical cleaning: 2~ 12
Maximum pressure drop of a single membrane element: 10psi (0.07Mpa)
Membrane element size
All units of the icon are: mm (inch)
FAQ
1. Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
2. Q: Should we use our logo/brand?
A: Yes, OEM is absolutely supported. But for some items quatity is 1000pcs
3. Q: What is the filtering accuracy of RO membrane?
A: RO meembran filtering accuracy is 0.0001um.
4.RO membrene desalination rate and service life ?
A: RO meembran desalination rate more 98%,service life according to water quality 2-3years
5. Q: What is the payment?
A: Usually we offer two payment terms: by Alibaba or by TT. L/C and D/A.
6. Q: How long time have your company in water treatment?
A: We have more than 21 years experience in water treatment equipment/water treatment solution.
On July 27, 2024, my colleague Carlson and I departed from Terminal 2 of Beijing Capital International Airport and arrived in Tashkent, the capital of Uzbekistan, after a 6-hour flight. Uzbekistan is an inland country in Central Asia. Russian is the common language, with a population of 36.8 million
On April 6, 2024, two representatives from our company, Youmankang, arrived in Lebanon, a country in the Middle East known for its breathtaking landscapes. With buildings nestled on hillsides, water trucks can be seen everywhere on the streets, indicating the underdeveloped seawater desalination tec
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to