Seawater Ro Systems Reverse Osmosis Ro Membrane introduction
Seawater reverse osmosis systems are designed to decline more than 99% of saline compromised within the feed water. These systems also incorporate a rinsing, chemical purifying apparatus to eliminate sodium chloride, avert scaling, and preserve system performance. There are two fundamental elements within every seawater reverse osmosis system, which are reverse osmosis membranes and high pressure feed pumps. These elements make up the center of any reverse osmosis system and need special consideration and application for successful operation.
Specifications and Major Properties
Model | Active Membrane Area ft2(m2) | Permeate flow GPD(m3/d) | Stable Rejecion Rate% |
SW8040XHR-400 | 400 ( 37.2 ) | 6000 (22.7 ) | 99.85 |
SW8040XHR- 440 | 440 ( 40.9) | 6600 (25.0) | 99.85 |
SW8040FR-400 | 400 (37.2) | 8200 (31.0) | 99.8 |
SW8040HR-400 | 400 (37.2) | 7500 ( 28.4 ) | 99.8 |
SW8040HR-440 | 440 ( 40.9 ) | 8250 (31.2) | 99.8 |
SW8040LE-400 | 400 ( 37.2 ) | 9000 ( 34.0 ) | 99.8 |
SW8040LE-440 | 400 ( 40.9) | 9500 ( 35.9 ) | 99.8 |
SW8040XLE-400 | 400 (37.2 ) | 11000 (41.6) | 99.7 |
SW8040XLE-440 | 440 ( 40.9 ) | 12100 ( 45.8) | 99.7 |
SW4040HR | 95(8.8) | 1600(6.1) | 99.8 |
SW4040LE | 95(8.8) | 1900 ( 7.2 ) | 99.7 |
SW11-4021 | 33(3.1) | 750(2.8) | 99.5 |
SW11-2521 | 12( 1.1 ) | 270 (1.0) | 99.5 |
SW11-2540 | 28(2.6) | 600(2.3) | 99.5 |
Membrane size
Membrane package and shipping
Vontron Authorization
Seawater Ro Systems Reverse Osmosis Ro Membrane introduction
Seawater reverse osmosis systems are designed to decline more than 99% of saline compromised within the feed water. These systems also incorporate a rinsing, chemical purifying apparatus to eliminate sodium chloride, avert scaling, and preserve system performance. There are two fundamental elements within every seawater reverse osmosis system, which are reverse osmosis membranes and high pressure feed pumps. These elements make up the center of any reverse osmosis system and need special consideration and application for successful operation.
Specifications and Major Properties
Model | Active Membrane Area ft2(m2) | Permeate flow GPD(m3/d) | Stable Rejecion Rate% |
SW8040XHR-400 | 400 ( 37.2 ) | 6000 (22.7 ) | 99.85 |
SW8040XHR- 440 | 440 ( 40.9) | 6600 (25.0) | 99.85 |
SW8040FR-400 | 400 (37.2) | 8200 (31.0) | 99.8 |
SW8040HR-400 | 400 (37.2) | 7500 ( 28.4 ) | 99.8 |
SW8040HR-440 | 440 ( 40.9 ) | 8250 (31.2) | 99.8 |
SW8040LE-400 | 400 ( 37.2 ) | 9000 ( 34.0 ) | 99.8 |
SW8040LE-440 | 400 ( 40.9) | 9500 ( 35.9 ) | 99.8 |
SW8040XLE-400 | 400 (37.2 ) | 11000 (41.6) | 99.7 |
SW8040XLE-440 | 440 ( 40.9 ) | 12100 ( 45.8) | 99.7 |
SW4040HR | 95(8.8) | 1600(6.1) | 99.8 |
SW4040LE | 95(8.8) | 1900 ( 7.2 ) | 99.7 |
SW11-4021 | 33(3.1) | 750(2.8) | 99.5 |
SW11-2521 | 12( 1.1 ) | 270 (1.0) | 99.5 |
SW11-2540 | 28(2.6) | 600(2.3) | 99.5 |
Membrane size
Membrane package and shipping
Vontron Authorization
On June 6, 2025, the 17th Watertech China successfully wrapped up its three-day event at the National Exhibition and Convention Center (Hongqiao) in Shanghai. As one of the world’s leading trade shows for the water treatment industry, it brought together cutting-edge technologies and innovative prod
1. Water Quality in CanadaIn Canada's Shield area, water is relatively soft because hard rocks do not release much calcium into the water. However, in regions with more limestone than granite, large amounts of calcium dissolve into the water, making it hard. The water hardness in these areas usually
The 2025 WQA Convention & Exposition was held from April 22 to 24 at the Long Beach Convention Center in California, USA. The exhibition area covered more than 25,000 square meters. As an authoritative annual event in the North American water treatment industry, it attracted over 400 exhibitors and