Seawater Ro Systems Reverse Osmosis Ro Membrane introduction
Seawater reverse osmosis systems are designed to decline more than 99% of saline compromised within the feed water. These systems also incorporate a rinsing, chemical purifying apparatus to eliminate sodium chloride, avert scaling, and preserve system performance. There are two fundamental elements within every seawater reverse osmosis system, which are reverse osmosis membranes and high pressure feed pumps. These elements make up the center of any reverse osmosis system and need special consideration and application for successful operation.
Specifications and Major Properties
Model | Active Membrane Area ft2(m2) | Permeate flow GPD(m3/d) | Stable Rejecion Rate% |
SW8040XHR-400 | 400 ( 37.2 ) | 6000 (22.7 ) | 99.85 |
SW8040XHR- 440 | 440 ( 40.9) | 6600 (25.0) | 99.85 |
SW8040FR-400 | 400 (37.2) | 8200 (31.0) | 99.8 |
SW8040HR-400 | 400 (37.2) | 7500 ( 28.4 ) | 99.8 |
SW8040HR-440 | 440 ( 40.9 ) | 8250 (31.2) | 99.8 |
SW8040LE-400 | 400 ( 37.2 ) | 9000 ( 34.0 ) | 99.8 |
SW8040LE-440 | 400 ( 40.9) | 9500 ( 35.9 ) | 99.8 |
SW8040XLE-400 | 400 (37.2 ) | 11000 (41.6) | 99.7 |
SW8040XLE-440 | 440 ( 40.9 ) | 12100 ( 45.8) | 99.7 |
SW4040HR | 95(8.8) | 1600(6.1) | 99.8 |
SW4040LE | 95(8.8) | 1900 ( 7.2 ) | 99.7 |
SW11-4021 | 33(3.1) | 750(2.8) | 99.5 |
SW11-2521 | 12( 1.1 ) | 270 (1.0) | 99.5 |
SW11-2540 | 28(2.6) | 600(2.3) | 99.5 |
Membrane size
Membrane package and shipping
Vontron Authorization
Seawater Ro Systems Reverse Osmosis Ro Membrane introduction
Seawater reverse osmosis systems are designed to decline more than 99% of saline compromised within the feed water. These systems also incorporate a rinsing, chemical purifying apparatus to eliminate sodium chloride, avert scaling, and preserve system performance. There are two fundamental elements within every seawater reverse osmosis system, which are reverse osmosis membranes and high pressure feed pumps. These elements make up the center of any reverse osmosis system and need special consideration and application for successful operation.
Specifications and Major Properties
Model | Active Membrane Area ft2(m2) | Permeate flow GPD(m3/d) | Stable Rejecion Rate% |
SW8040XHR-400 | 400 ( 37.2 ) | 6000 (22.7 ) | 99.85 |
SW8040XHR- 440 | 440 ( 40.9) | 6600 (25.0) | 99.85 |
SW8040FR-400 | 400 (37.2) | 8200 (31.0) | 99.8 |
SW8040HR-400 | 400 (37.2) | 7500 ( 28.4 ) | 99.8 |
SW8040HR-440 | 440 ( 40.9 ) | 8250 (31.2) | 99.8 |
SW8040LE-400 | 400 ( 37.2 ) | 9000 ( 34.0 ) | 99.8 |
SW8040LE-440 | 400 ( 40.9) | 9500 ( 35.9 ) | 99.8 |
SW8040XLE-400 | 400 (37.2 ) | 11000 (41.6) | 99.7 |
SW8040XLE-440 | 440 ( 40.9 ) | 12100 ( 45.8) | 99.7 |
SW4040HR | 95(8.8) | 1600(6.1) | 99.8 |
SW4040LE | 95(8.8) | 1900 ( 7.2 ) | 99.7 |
SW11-4021 | 33(3.1) | 750(2.8) | 99.5 |
SW11-2521 | 12( 1.1 ) | 270 (1.0) | 99.5 |
SW11-2540 | 28(2.6) | 600(2.3) | 99.5 |
Membrane size
Membrane package and shipping
Vontron Authorization
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to
We are excited to invite you to visit Booth No. 238 at the upcoming 2024 WQA exhibition in Orlando, FL, USA. At our booth, we will be showcasing a range of cutting-edge water treatment solutions, including our flagship product, RO membranes.Reverse Osmosis (RO) membranes are at the heart of our wate
Reverse osmosis membranes play a crucial role in water purification by effectively removing dissolved salts, colloids, microorganisms, and organic compounds. However, the performance of these membranes can deteriorate due to various factors such as surface fouling, physical and chemical changes, and