Availability: | |
---|---|
Quantity: | |
Brief Introduction
Low Pressure Series Membrane Elements are manufactured using the industrys leading patented membrane film technology and offer reliability, high performance and deliver consistent results. They offer increased production, high rejection rates and low energy consumption by operating at low applied pressures.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
IWL 21-8040 | 10000(37.8) | 99.5 | 99.2 |
IML 22-8040 | 11000(41.5) | 99.5 | 99.2 |
IWL 21-4040 | 2500(9.4) | 99.5 | 99.2 |
Testing Conditions:
Testing Pressure: 225 psi (1.55Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 2000ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4. 14Mpa)
Max. Feedwater Flow: 75gpm(17 m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater T emperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwater: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0.1Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
Product Advantages
Low Pressure
High Flow Capacities
Improved System Performance
Superior Quality and Cost Savings
Individually Tested
If you would like to know more about our RO membranes, please contact us!
Brief Introduction
Low Pressure Series Membrane Elements are manufactured using the industrys leading patented membrane film technology and offer reliability, high performance and deliver consistent results. They offer increased production, high rejection rates and low energy consumption by operating at low applied pressures.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
IWL 21-8040 | 10000(37.8) | 99.5 | 99.2 |
IML 22-8040 | 11000(41.5) | 99.5 | 99.2 |
IWL 21-4040 | 2500(9.4) | 99.5 | 99.2 |
Testing Conditions:
Testing Pressure: 225 psi (1.55Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 2000ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4. 14Mpa)
Max. Feedwater Flow: 75gpm(17 m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater T emperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwater: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0.1Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
Product Advantages
Low Pressure
High Flow Capacities
Improved System Performance
Superior Quality and Cost Savings
Individually Tested
If you would like to know more about our RO membranes, please contact us!
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to
We are excited to invite you to visit Booth No. 238 at the upcoming 2024 WQA exhibition in Orlando, FL, USA. At our booth, we will be showcasing a range of cutting-edge water treatment solutions, including our flagship product, RO membranes.Reverse Osmosis (RO) membranes are at the heart of our wate
Reverse osmosis membranes play a crucial role in water purification by effectively removing dissolved salts, colloids, microorganisms, and organic compounds. However, the performance of these membranes can deteriorate due to various factors such as surface fouling, physical and chemical changes, and