Availability: | |
---|---|
Quantity: | |
Brief Introduction
BW reverse osmosis membranes are designed to provide high salt rejection at a standard operating pressure of 225psi for tap water, surface water, groundwater and municipal water applications.
Brackish water membranes are superior to low pressure elements, providing better salt rejection but requiring more operating energy.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
BW30HR-8040 | 10500(39.7) | 99.75 | 99.4 |
BW30HR-4040 | 2500(9.5) | 99.7 | 99.4 |
Testing Conditions:
Testing Pressure: 225 psi (1.55Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCI): 2000ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4.14Mpa)
Max. Feedwater Flow: 75gpm(17m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwate: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0. 1Mpa)
Dimensions of Membrane Element
All dlimensions are shown in: millimeter (inch)
Brief Introduction
BW reverse osmosis membranes are designed to provide high salt rejection at a standard operating pressure of 225psi for tap water, surface water, groundwater and municipal water applications.
Brackish water membranes are superior to low pressure elements, providing better salt rejection but requiring more operating energy.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
BW30HR-8040 | 10500(39.7) | 99.75 | 99.4 |
BW30HR-4040 | 2500(9.5) | 99.7 | 99.4 |
Testing Conditions:
Testing Pressure: 225 psi (1.55Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCI): 2000ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4.14Mpa)
Max. Feedwater Flow: 75gpm(17m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater Temperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwate: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0. 1Mpa)
Dimensions of Membrane Element