Availability: | |
---|---|
Quantity: | |
Product Advantages
RO membrane elements with end-locked connections, high effective membrane area and low energy consumption desalination reverse osmosis membrane elements with ultra-low energy consumption and single-stage design achieve the perfect combination of high productivity and high desalination rates and are ideally suited to isosaline and medium temperature feed water conditions. In addition, it is ideal for two-stage desalination designs or high salinity brackish water applications.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
IWL 21-8040 | 10000(37.8) | 99.5 | 99.2 |
IML 22-8040 | 1 1000(41.5) | 99.5 | 99.2 |
IWL 21-4040 | 2500(9.4) | 99.5 | 99.2 |
Testing Conditions:
Testing Pressure: 225 psi (1.55Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 2000ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4. 14Mpa)
Max. Feedwater Flow: 75gpm(17 m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater T emperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwater: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0.1Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
Operating Precautions
To prevent potential membrane damage during start-up, shutdown, cleaning or other processes, avoid any sudden pressure or mis-flow flow changes in the rolled element. During start-up, we recommend a gradual transition from standstill to operation according to the following procedure.
1. The feed water pressure should be gradually increased over a time frame of 30 to 60 seconds.
2. The increase to the design mis-flow rate should be reached gradually over a period of 15-20 seconds.
3. The product water should be drained and not used within the first hour.
Product Advantages
RO membrane elements with end-locked connections, high effective membrane area and low energy consumption desalination reverse osmosis membrane elements with ultra-low energy consumption and single-stage design achieve the perfect combination of high productivity and high desalination rates and are ideally suited to isosaline and medium temperature feed water conditions. In addition, it is ideal for two-stage desalination designs or high salinity brackish water applications.
Specifications and Major Properties
Model | Average Permeated Flow GPD (m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
IWL 21-8040 | 10000(37.8) | 99.5 | 99.2 |
IML 22-8040 | 1 1000(41.5) | 99.5 | 99.2 |
IWL 21-4040 | 2500(9.4) | 99.5 | 99.2 |
Testing Conditions:
Testing Pressure: 225 psi (1.55Mpa)
Temperature of Testing Solution: 25°C
Concentration of Testing Solution (NaCl): 2000ppm
pH Value of Testing Solution: 7.5
Recovery Rate of Single Membrane Element: 15%
Extreme Operation Conditions
Max. Working Pressure: 600psi(4. 14Mpa)
Max. Feedwater Flow: 75gpm(17 m3/h) (8040)
16gpm (3.6 m3/h) (4040)
Max. Feedwater T emperature: 45°C
Max. Feedwater SDI: 5
Residual chlorine Concentration of Feedwater: < 0.1ppm
pH Range of Feedwater during Continuous Operation: 3~10
pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 15psi(0.1Mpa)
Dimensions of Membrane Element
All dimensions are shown in: millimeter (inch)
Operating Precautions
To prevent potential membrane damage during start-up, shutdown, cleaning or other processes, avoid any sudden pressure or mis-flow flow changes in the rolled element. During start-up, we recommend a gradual transition from standstill to operation according to the following procedure.
1. The feed water pressure should be gradually increased over a time frame of 30 to 60 seconds.
2. The increase to the design mis-flow rate should be reached gradually over a period of 15-20 seconds.
3. The product water should be drained and not used within the first hour.
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to
We are excited to invite you to visit Booth No. 238 at the upcoming 2024 WQA exhibition in Orlando, FL, USA. At our booth, we will be showcasing a range of cutting-edge water treatment solutions, including our flagship product, RO membranes.Reverse Osmosis (RO) membranes are at the heart of our wate
Reverse osmosis membranes play a crucial role in water purification by effectively removing dissolved salts, colloids, microorganisms, and organic compounds. However, the performance of these membranes can deteriorate due to various factors such as surface fouling, physical and chemical changes, and