The 150 GPD membrane has a 98% retention rate at 65 PSI, making it the most commonly used membrane when speed is critical. If you need faster effluent velocity and good water pressure, this is one of the better options.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
FAQ
1. Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
2. Q: Should we use our logo/brand?
A: Yes, OEM is absolutely supported. But for some items quatity is 1000pcs
3. Q: What is the filtering accuracy of RO membrane?
A: RO meembran filtering accuracy is 0.0001um.
4.RO membrene desalination rate and service life ?
A: RO meembran desalination rate more 98%,service life according to water quality 2-3years
5. Q: What is the payment?
A: Usually we offer two payment terms: by Alibaba or by TT. L/C and D/A.
6. Q: How long time have your company in water treatment?
A: We have more than 21 years experience in water treatment equipment/water treatment solution.
Membrane element size
All units of the icon are: mm (inch)
Important information
1. The water production listed in the table is an average value, and the difference between the minimum water production of a single membrane element and the nominal value does not exceed 20% of the nominal value.
2. Wet-type membrane elements have been strictly tested before leaving the factory, and use 1 .0% sodium bisulfite (10% propylene glycol antifreeze in winter) solution for storage treatment, and then vacuum packaging, the outer packaging is Cardboard box. In order to prevent the growth of microorganisms during short-term storage, transportation and system standby, it is recommended to soak the components with a protective solution (prepared with RO produced water) containing 1 .0% sodium bisulfite (food grade).
3. The RO produced water in the first hour of operation should be discharged.
4. It is forbidden to add any chemical agents that have an impact on membrane elements during storage and operation.
Notes
If you are replacing a membrane, it is a good idea to replace the drain restrictor on your reverse osmosis system. It may become clogged with years of use (meaning you don't have enough flow to properly flush impurities from the membrane surface, leading to premature membrane failure), or if you are installing a larger or smaller membrane, the flow restrictor needs to be replaced.
The 150 GPD membrane has a 98% retention rate at 65 PSI, making it the most commonly used membrane when speed is critical. If you need faster effluent velocity and good water pressure, this is one of the better options.
Specifications and main performance of membrane elements
Type | Model | Reject (%) | Average Permeate GPD (m3/d) | Working Pressure & Application | Testing Conditions | ||
Pressure psi (MPa) | Solution Concentr. (PPm) | Recovery Rate (%) | |||||
Household RO Membrane | UM1812-50 | 99.0 | 50(0.2) | Working under extremely low pressure. Applicable to residential water purifier and water purifying devices in hospital and laboratory water treatment with TDS lower than 500 ppm. | 60 (0.41) | 250 | 15 |
UM1810-50 | 97.0 | 50(0.2) | |||||
UM1812-75HR | 99.0 | 75 (0.28) | |||||
UM1812-75 | 97.0 | 75 (0.28) | |||||
UM-2012-100HR | 99.0 | 100 (0.38) | |||||
UM-2012-100 | 97.5 | 100 (0.38) | |||||
UM-2012-150 | 97.5 | 150(0.57) | |||||
Special Size RO Membrane | UM-2812-200 | 97.0 | 200(0.76) | working under extremely low pressure. Applicable to automatic water dispenser and residential drinking fountain. | 100 (0.69) | 250 | 20 |
UM-3012-300 | 97.0 | 300(1.14) | 100 (0.69) | 250 | 20 | ||
UM-3012-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3013-400 | 97.0 | 400(1.51) | 100 (0.69) | 250 | 20 | ||
UM-3012-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-500 | 97.0 | 500(1.89) | 100 (0.69) | 250 | 20 | ||
UM-3013-600 | 97.0 | 600(2.27) | 100 (0.69) | 250 | 20 | ||
UM-3013-700 | 97.0 | 700(2.65) | 100 (0.69) | 250 | 20 |
FAQ
1. Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
2. Q: Should we use our logo/brand?
A: Yes, OEM is absolutely supported. But for some items quatity is 1000pcs
3. Q: What is the filtering accuracy of RO membrane?
A: RO meembran filtering accuracy is 0.0001um.
4.RO membrene desalination rate and service life ?
A: RO meembran desalination rate more 98%,service life according to water quality 2-3years
5. Q: What is the payment?
A: Usually we offer two payment terms: by Alibaba or by TT. L/C and D/A.
6. Q: How long time have your company in water treatment?
A: We have more than 21 years experience in water treatment equipment/water treatment solution.
Membrane element size
All units of the icon are: mm (inch)
Important information
1. The water production listed in the table is an average value, and the difference between the minimum water production of a single membrane element and the nominal value does not exceed 20% of the nominal value.
2. Wet-type membrane elements have been strictly tested before leaving the factory, and use 1 .0% sodium bisulfite (10% propylene glycol antifreeze in winter) solution for storage treatment, and then vacuum packaging, the outer packaging is Cardboard box. In order to prevent the growth of microorganisms during short-term storage, transportation and system standby, it is recommended to soak the components with a protective solution (prepared with RO produced water) containing 1 .0% sodium bisulfite (food grade).
3. The RO produced water in the first hour of operation should be discharged.
4. It is forbidden to add any chemical agents that have an impact on membrane elements during storage and operation.
Notes
If you are replacing a membrane, it is a good idea to replace the drain restrictor on your reverse osmosis system. It may become clogged with years of use (meaning you don't have enough flow to properly flush impurities from the membrane surface, leading to premature membrane failure), or if you are installing a larger or smaller membrane, the flow restrictor needs to be replaced.
On July 27, 2024, my colleague Carlson and I departed from Terminal 2 of Beijing Capital International Airport and arrived in Tashkent, the capital of Uzbekistan, after a 6-hour flight. Uzbekistan is an inland country in Central Asia. Russian is the common language, with a population of 36.8 million
On April 6, 2024, two representatives from our company, Youmankang, arrived in Lebanon, a country in the Middle East known for its breathtaking landscapes. With buildings nestled on hillsides, water trucks can be seen everywhere on the streets, indicating the underdeveloped seawater desalination tec
Why should the RO membrane system with reverse osmosis scale inhibitor be pretreated?The purpose of pretreatment is to remove or reduce the substances in the feed water that may cause membrane contamination, scaling and damage to the permissible range of the reverse osmosis membrane system, so as to